0-5V/0-10V/4-20MA/RS485 Solar irradiance sensor transmitter meteorological outdoor solar radiation detector sensor
0-5V/0-10V/4-20MA/RS485 Solar irradiance sensor transmitter meteorological outdoor solar radiation detector sensor
0-5V/0-10V/4-20MA/RS485 Solar irradiance sensor transmitter meteorological outdoor solar radiation detector sensor
Analog output
- Power supply range : 10V~30V DC (0-10V output supply voltage needs 24VDC)
- Output : 4-20mA, 0-5V, 0-10V
- Maximum power consumption
- Current output: 0.08W
- Voltage output: 0.08W
- Working humidity: 0%~100%RH
- Working temperature :-40 C ~ 60 C
- Spectral range :0.3~3μm
- Measuring range: 0~1800W/m2
- Resolution :1W/m2
- Response time <=10S
- Nonlinear <+-2%
- Annual stability <+-2%
- Cosine response <+-10%
- Line length 60cm
Wiring
|
Wire color |
Description |
Power |
Brown |
Power supply (10~30V DC) |
Black |
Power- |
|
Communication |
Blue |
Signal+ |
Green |
Signal- |
Calculation formula
Current type signal output calculation method
For example, the range is 0~1800W/m2, 4~20mA output. When the output signal is 12mA, the current solar radiation value is calculated.
The solar radiation range spans 1800 W/m2 and is expressed by a 16 mA current signal, 1800 W/m2/16 mA = 112.5 W/m2. /mA, that is, current 1mA represents solar radiation change 112.5W/m2, measured value 12mA-4mA=8mA, 8mA*112.5W/
M2/mA = 900W/m2, the current solar radiation value is 900W/m2.
Voltage type signal output conversion calculation
For example, the range is 0~1800W/m2, 0-10V output. When the output signal is 5V, the current solar radiation value is calculated. sun
The span of the radiation range is 1800W/m2, expressed by a 10V voltage signal, 1800W/m2/10V=180W/m2/V, that is, electricity
Pressure 1V represents solar radiation change 180W/m2, measured value 5V-0V=5V, 5V*180W/m2/V=900W/m2, current sun
The radiation value is 900 W/m2.
RS485 Output
- Power supply range :10V~30V DC
- Output : RS 485 (standard Modbus-RTU protocol)
- Power consumption :0.08W
- Working humidity: 0%~100%RH
- Working temperature: -40 C ~ 60 C
- Spectral range: 0.3~3μm
- Measuring range : 0~1800W/m2
- Resolution :1W/m2
- Response time :≤ 10S
- Nonlinear: <±2%
- Annual stability :≤ ± 2%
- Cosine response: ≤ ± 10%
- Line length : 60cm
Wiring
|
Wire color |
Description |
Power |
Brown |
Power supply (10~30V DC) |
Black |
Power- |
|
Communication |
Yellow |
485+ |
Blue |
485- |
Installation method
- After the installation is complete, remove the protective cover
- Make sure the bracket is installed and the radiation sensor is parallel to the ground.
- Secure the sensor to the mounting bracket by using a screw through the mounting hole on the sensor.
- Please note that the dust cover should not be damaged during the installation process, so as not to affect the measurement accuracy.
Product size
provide config tool